Analysis of the stray magnetic field created by faulty electrical machines

V.P. Bui (Grenoble Electrical Engineering Laboratory, Domaine Universitaire, Saint Martin d'Hères, France)
O. Chadebec (Grenoble Electrical Engineering Laboratory, Domaine Universitaire, Saint Martin d'Hères, France)
L‐L. Rouve (Grenoble Electrical Engineering Laboratory, Domaine Universitaire, Saint Martin d'Hères, France)
J‐L. Coulomb (Grenoble Electrical Engineering Laboratory, Domaine Universitaire, Saint Martin d'Hères, France)
287

Abstract

Purpose

This paper aims to compute the magnetic stray field created by faulty electrical machines.

Design/methodology/approach

This paper proposes two approaches to compute the magnetic stray field created by faulty electrical machines. The first one presents a homogenized FEM method. The second one is based on a combination of an analytical expression for the magnetic field in the machine air gap with an integral method.

Findings

The studies show good agreement and demonstrate the reliability of the approach.

Originality/value

Two models developed in this paper originally used to compute the stray magnetic field of electrical machines. They can contribute to develop new tools for fault monitoring.

Keywords

Citation

Bui, V.P., Chadebec, O., Rouve, L. and Coulomb, J. (2008), "Analysis of the stray magnetic field created by faulty electrical machines", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 27 No. 1, pp. 224-234. https://doi.org/10.1108/03321640810836780