To read this content please select one of the options below:

Evaluation of rebar corrosion in reinforced concrete under freeze-thaw environment and protection measures

Zhiming Ma (Department of Structural Engineering, Tongji University, Shanghai,China.)
Tiejun Zhao (College of Civil Engineering, Qingdao Technological University, Qingdao, China.)
Jianzhuang Xiao (Department of Structural Engineering, Tongji University, Shanghai, China.)
Ting Guan (College of Civil Engineering, Qingdao Technological University, Qingdao, China.)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 7 March 2016

422

Abstract

Purpose

Rebar corrosion in reinforced concrete is the major reason for the durability degradation, especially under harsh environment. This paper presents an experiment conducted to investigate the influence of freeze-thaw cycles on the rebar corrosion in reinforced concrete. The purpose of this paper is to provide fundamental information about rebar corrosion under frost environment and improvement measures.

Design/methodology/approach

The related elastic modulus and compressive strength of different concrete specimens were measured after different freeze-thaw cycles. The accelerated rebar corrosion test was carried out after different freeze-thaw cycles; additionally, the value of calomel half-cell potential was determined. The actual rebar corrosion appearance was checked to prove the accuracy of the results of calomel half-cell potential.

Findings

The results show that frost damage aggravates the rebar corrosion rate and degree under freeze-thaw environment; furthermore, the results become more obvious with the freeze-thaw cycles increasing. Mixing the air-entrained agent into fresh concrete to prepare air-entrained concrete, increasing the cover thickness and processing the surface of concrete with a waterproofing agent can significantly improve the resistance to rebar corrosion. From the actual appearance of rebar corrosion, the results of calomel half-cell potential can well reflect the actual rebar corrosion in reinforced concrete.

Originality/value

The durability of reinforced concrete is mainly determined on chloride penetration that brings about rebar corrosion in chloride environments. Furthermore, the degradation of concrete durability becomes more serious in the harsh environment. As the concrete exposure to the freeze-thaw cycles environment, the freeze-thaw cycles accelerate the concrete damage, and the penetration of chloride into the concrete becomes easier because of the growing pore and crack sizes. In addition, rebar corrosion caused by chloride is one of the major forms of environmental attack on reinforced concrete. The tests conducted in this paper will describe the rebar corrosion in reinforced concrete under freeze-thaw environment.

Keywords

Acknowledgements

The authors would like to acknowledge the financial support of the National Natural Science Foundation of China (51178340, 50739001), 973 Project (2009CB623203) and Key Projects in the National Science & Technology Pillar Program.

Citation

Ma, Z., Zhao, T., Xiao, J. and Guan, T. (2016), "Evaluation of rebar corrosion in reinforced concrete under freeze-thaw environment and protection measures", Anti-Corrosion Methods and Materials, Vol. 63 No. 2, pp. 128-136. https://doi.org/10.1108/ACMM-11-2014-1461

Publisher

:

Emerald Group Publishing Limited

Copyright © 2016, Emerald Group Publishing Limited

Related articles