Abstract

Purpose

The purpose of this paper is to introduce a significant modification of the sensitivity maps calculation process using electric field distribution analysis. A sensitivity matrix is typically a crucial part of a deterministic image reconstruction process in a three-dimensional capacitance tomography (3D ECT) and strictly decides about a final image quality. Commonly used sensitivity matrix computation methods mostly provide acceptable results and additionally allow to perform a recalculation of sensitivity maps according to the changing permittivity distribution.

Design/methodology/approach

The new “tunnel-based” algorithm is proposed which traces the surfaces constructed along the electric field lines. The new solution is developed and tested using experimental data.

Findings

To fully validate the new technique both linear and non-linear image reconstruction processes were performed and the criteria of image error estimation were discussed. This paper discusses some preliminary results of the image reconstruction process using the new proposed algorithm. As a result of this research, an increased accuracy of the new method is proved.

Originality/value

The presented results of image reconstruction with new sensitivity matrix in comparison with the classic matrix proved that the new solution is able to improve the convergence and stability of image reconstruction process for 3D ECT imaging.

Keywords

Acknowledgements

This work is partially co-funded by The Rector of Lodz University of Technology (LUT) in Poland and The Dean of The Faculty of Electrical, Electronic, Computer and Control Engineering at the LUT, in the frame of young researchers supporting programme. This work is partially supported by the Polish Committee of Science and Research (Project number 4,664/B/T02/2010/38).

Citation

Wajman, R. and Banasiak, R. (2014), "Tunnel-based method of sensitivity matrix calculation for 3D-ECT imaging", Sensor Review, Vol. 34 No. 3, pp. 273-283. https://doi.org/10.1108/SR-06-2013-692

Publisher

:

Emerald Group Publishing Limited

Copyright © 2014, Emerald Group Publishing Limited

Related articles