To read this content please select one of the options below:

Numerical study on the effect of pillar material on the frequency shift of coupled quartz crystal resonator with pillar

Yi Xie (School of Information Science and Engineering, Lanzhou University, Lanzhou, China)
Baojin Zheng (School of Information Science and Engineering, Lanzhou University, Lanzhou, China)

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 22 August 2023

7

Abstract

Purpose

This paper aims to apply the novel numerical model to analyze the effect of pillar material on the response of compound quartz crystal resonator (QCR) with an array of pillars. The performance of the proposed device compared to conventional QCR method was also investigated.

Design/methodology/approach

A finite element method model was developed to analyze the behavior of QCR coupled with an array of pillars. The model was composed of an elastic pillar, a solution and a perfectly matched layer. The validation of the model was performed through a comparison between its predictions and previous experimental measurements. Notably, a good agreement was observed between the predicted results and the experimental data.

Findings

The effect of pillar Young’s modulus on the coupled QCR and pillars with a diameter of 20 µm, a center-to-center spacing of 40 µm and a density of 2,500 kg/m3 was investigated. The results indicate that multiple vibration modes can be obtained based on Young’s modulus. Notably, in the case of the QCR–pillar in air, the second vibration mode occurred at a critical Young’s modulus of 0.2 MPa, whereas the first mode was observed at 3.75 Mpa. The vibration phase analysis revealed phase-veering behavior at the critical Young’s modulus, which resulted in a sudden jump-and-drop frequency shift. In addition, the results show that the critical Young’s modulus is dependent on the surrounding environment of the pillar. For instance, the critical Young’s modulus for the first mode of the pillar is approximately 3.75 Mpa in air, whereas it increases to 6.5 Mpa in water.

Originality/value

It was concluded that the performance of coupled QCR–pillar devices significantly depends on the pillar material. Therefore, choosing pillar material at critical Young’s modulus can lead to the maximum frequency shift of coupled QCR–pillar devices. The model developed in this work helps the researchers design pillars to achieve maximum frequency shift in their measurements using coupled QCR–pillar.

Keywords

Citation

Xie, Y. and Zheng, B. (2023), "Numerical study on the effect of pillar material on the frequency shift of coupled quartz crystal resonator with pillar", World Journal of Engineering, Vol. ahead-of-print No. ahead-of-print. https://doi.org/10.1108/WJE-03-2023-0068

Publisher

:

Emerald Publishing Limited

Copyright © 2023, Emerald Publishing Limited