Shaking table test on building in masonry structure with construction waste recycled brick

1 School of Hydraulic and Hydro-power, Hebei University of Engineering, Handan 056021, China

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 1 August 2014

Issue publication date: 1 August 2014

92

Abstract

Based on the shake table test on "tie column-ring beam-cast-in-place slab" construction waste recycled brick masonry structure, a 1/3 scaled model of 4 stories is tested to analyze the seismic behavior of the multi-storey masonry structure. The test is conducted with EL-Centro seismic wave, Taft wave and artificial wave to simulate the damages observed and the seismic response under different earthquake levels. On the basis of test results, the seismic performance of the model is good and the overall structure could satisfy seismic fortification requirements in the region of intensity 8. At the same time, there was no obvious difference between this masonry structure and recycled aggregate concrete block masonry structure. The lintel of the door and window damage seriously. The base damages more easily than the superstructure. Masonry structure with construction waste recycled brick can satisfy the requirement of the masonry structure buildings in eight degree of aseismatic design area.

Keywords

Citation

Su, H., Wang, J., Jiang, X. and Tan, Y. (2014), "Shaking table test on building in masonry structure with construction waste recycled brick", World Journal of Engineering, Vol. 11 No. 4, pp. 357-364. https://doi.org/10.1260/1708-5284.11.4.357