To read this content please select one of the options below:

Parametric study on load ratio effect on the flexural bending behaviour of axially-restrained HSS steel beams subjected to fire

Osama (Sam) Salem (Department of Civil Engineering, Lakehead University, Ontario, Canada)

Journal of Structural Fire Engineering

ISSN: 2040-2317

Article publication date: 29 March 2018

Issue publication date: 16 October 2018

131

Abstract

Purpose

In fire condition, the limiting temperature of a restrained steel beam depends on a few parameters, e.g. temperature distributions along and across the beam, beam’s load ratio and span length. The purpose of this study is to investigate the structural fire behaviour of axially restrained steel beams under different beam’s load ratios, taking into consideration the effect of the beam’s end connections configuration.

Design/methodology/approach

A three-dimensional finite element (FE) computer model has been developed to simulate the structural fire behaviour of axially restrained steel beams and their end connections. After successfully validating the developed model against the outcomes of the available large-size fire resistance experiments, the FE model has been used in a parametric study to investigate the beam’s load ratio effect on the behaviour of the axially restrained steel beams and their end connections.

Findings

The parametric study showed that increasing the beam loading level significantly increased the beam deflections at elevated temperatures; where, increasing the beam’s load ratio from 0.5 to 0.9 reduced the beam fire resistance by about 100 s. In contrast, decreasing the beam’s load ratio from 0.5 to 0.3 allowed the beam to easily achieve a 30-min fire resistance rating with no fire protection applied.

Originality/value

Experimental parametric studies are difficult to control in a laboratory setting and are also expensive and time consuming. Therefore, the reasonable accuracy of the validated FE model in reproducing the experimental fire behaviour of steel beams and their end connections makes it a very useful tool for both numerical and analytical studies.

Keywords

Citation

Salem, O.(S). (2018), "Parametric study on load ratio effect on the flexural bending behaviour of axially-restrained HSS steel beams subjected to fire", Journal of Structural Fire Engineering, Vol. 9 No. 4, pp. 342-360. https://doi.org/10.1108/JSFE-10-2017-0042

Publisher

:

Emerald Publishing Limited

Copyright © 2018, Emerald Publishing Limited