To read this content please select one of the options below:

Influence of operational parameters on performance of twin thermoacoustic prime mover – CFD studies

Jabbar P ( National Institute of Technology Tiruchirappalli India )
Hariharan N.M ( Sree Sastha Institute of Engineering and Technology Chennai India )
Palani Sivashanmugam ( National Institute of Technology Tiruchirapalli India )
S. Kasthurirengan ( Indian Institute of Science Bengaluru India )

Engineering Computations

ISSN: 0264-4401

Article publication date: 11 March 2016

171

Abstract

Purpose

The present investigation deals with the analysis of the performance of twin thermoacoustic prime mover (TAPM) which are measured in terms of frequency and pressure amplitude by varying the parameters such as temperature gradient along the length of stack and the operating pressures of fluid medium argon using CFD simulation. With the help of CFD researchers and Engineers can evaluate the performance of a wide range of thermoacoustic systems on the computer without the time, expense, and disruption required to make actual changes onsite (stack) which is tedious to fabricate.

Design/methodology/approach

For the present simulation, the operating pressures of argon such as 1bar, 3bar and 5bar, and the temperature gradient is varied from 600K to 1400K with the regular intervals of each 200K. The geometry of twin TAPM is created using GAMBIT processor, and the simulation is carried out using FLUENT. The geometrical parameters of twin TAPM are kept constant throughout the simulation. The results for frequency and pressure amplitude obtained from the CFD simulation of twin TAPM for various temperature gradient and operating pressures are analysed and reported.

Findings

The computational results of twin thermoacoustic prime mover shows an increase in pressure amplitude with an increase in the temperature gradient and also it increases with an increase in operating pressures of the fluid medium. The parameter operating pressures of the working fluid medium and the stack hot end temperature has no significant effect on the output, frequency.

Originality/value

Though several experimental works had been published based on the twin thermoacoustic prime mover, an attempt has been made in the present investigation for the first time to estimate the performance of twin thermoacoustic prime mover using CFD package (ANSYS-FLUENT) by varying temperature gradient. The temperature gradient and operating pressures were varied and the performance of twin thermoacoustic prime mover was measured in terms of frequency and pressure amplitude.

Citation

P, J., N.M, H., Sivashanmugam, P. and Kasthurirengan, S. (2016), "Influence of operational parameters on performance of twin thermoacoustic prime mover – CFD studies", Engineering Computations, Vol. 33 No. 3. https://doi.org/10.1108/EC-01-2015-0018

Publisher

:

Emerald Group Publishing Limited

Copyright © 2016, Emerald Group Publishing Limited

Related articles