To read this content please select one of the options below:

Numerical investigation of aspect ratio influences on Rayleigh–Bénard convection of Bingham fluids in vertical cylindrical annuli

Sahin Yigit (School of Engineering, Newcastle University, Newcastle upon Tyne, UK)
Nilanjan Chakraborty (School of Engineering, Newcastle University, Newcastle upon Tyne, UK)

International Journal of Numerical Methods for Heat & Fluid Flow

ISSN: 0961-5539

Article publication date: 12 December 2018

Issue publication date: 29 January 2019

88

Abstract

Purpose

This paper aims to conduct numerical simulations to investigate steady-state laminar Rayleigh–Bénard convection of yield stress fluids obeying Bingham model in rectangular cross-sectional cylindrical annular enclosures. In this investigation, axisymmetric simulations have been carried out for nominal Rayleigh number range Ra = 103 to 105, aspect ratio range AR = 0.25 to 4 (i.e. AR = H/L where H is the enclosure height and L is the difference between outer and inner radii) and normalised inner radius range ri/L = 0 to 16 (where ri is internal cylinder radius) for a nominal representative Prandtl number Pr = 500. Both constant wall temperature (CWT) and constant wall heat flux (CWHF) boundary conditions have been considered for differentially heated horizontal walls to analyse the effects of wall boundary condition.

Design/methodology/approach

The bi-viscosity Bingham model is used to mimic Bingham fluids for Rayleigh–Bénard convection of Bingham fluids in vertical cylindrical annuli. The conservation equations of mass, momentum and energy have been solved in a coupled manner using the finite volume method where a second-order central differencing scheme is used for the diffusive terms and a second-order up-wind scheme is used for the convective terms. The well-known semi-implicit method for pressure-linked equations algorithm is used for the coupling of the pressure and velocity.

Findings

It is found that the convective transport strengthens (weakens) with an increase in Ra (AR) for both Newtonian (i.e. Bn = 0) and Bingham fluids, regardless of the boundary conditions. Moreover, the strength of convection is stronger in the CWT configuration than that is for CWHF boundary condition due to higher temperature difference between horizontal walls for both Newtonian (i.e. Bn = 0) and Bingham fluids. The mean Nusselt number Nūcy does not show a monotonic increase with increasing Ra for AR = 1 and ri/L = 4 because of the change in flow pattern (i.e. number of convection rolls/cells) in the CWT boundary condition, whereas a monotonic increase of Nūcy with increasing Ra is obtained for the CWHF configuration. In addition, Nūcy increases with increasing ri/L and asymptotically approaches the corresponding value obtained for rectangular enclosures (ri/L → ∞) for both CWT and CWHF boundary conditions for large values of ri/L. It is also found that both the flow pattern and the mean Nusselt number Nūcy are dependent on the initial conditions for Bingham fluid cases, as hysteresis is evident for AR = 1 for both CWT and CWHF boundary conditions.

Originality value

Finally, the numerical findings have been used to propose a correlation for Nūcy in the range of 0.25 ≤ ri/L ≤ 16, 0.25 ≤ AR ≤ 2 and 5 × 104Ra ≤ 105 for the CWHF configuration.

Keywords

Citation

Yigit, S. and Chakraborty, N. (2019), "Numerical investigation of aspect ratio influences on Rayleigh–Bénard convection of Bingham fluids in vertical cylindrical annuli", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. 29 No. 1, pp. 251-279. https://doi.org/10.1108/HFF-03-2018-0101

Publisher

:

Emerald Publishing Limited

Copyright © 2018, Emerald Publishing Limited

Related articles