Identification of defected sensors in an array of amperometric gas sensors

Marta Dmitrzak (Department of Biomedical Engineering, Gdansk University of Technology, Gdansk, Poland)
Pawel Kalinowski (Department of Biomedical Engineering, Gdansk University of Technology, Gdansk, Poland)
Piotr Jasinski (Department of Biomedical Engineering, Gdansk University of Technology, Gdansk, Poland)
Grzegorz Jasinski (Department of Biomedical Engineering, Gdansk University of Technology, Gdansk, Poland)

Sensor Review

ISSN: 0260-2288

Article publication date: 17 December 2021

Issue publication date: 8 March 2022

116

Abstract

Purpose

Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty.

Design/methodology/approach

In this work, the authors present the results obtained with six amperometric sensors. An array of sensors was exposed to sulfur dioxide at the following concentrations: 0 ppm (synthetic air), 50 ppb, 100 ppb, 250 ppb, 500 ppb and 1000 ppb. The damage simulation consisted in adding to the sensor response a value of 0.05 and 0.1 µA and replacing the responses of one of sensors with a constant value of 0 and 0.15 µA. Sensor validity index was used to identify a damaged sensor in the matrix, and its responses were corrected via iteration method.

Findings

The results show that the methods used in this work can be potentially applied to detect faulty sensor responses. In the case of simulation of damage by baseline shift, it was possible to achieve 100% accuracy in damage detection and identification of the damaged sensor. The method was not very successful in simulating faults by replacing the sensor response with a value of 0 µA, due to the fact that the sensors mostly gave responses close to 0 µA, as long as they did not detect SO2 concentrations below 250 ppb and the failure was treated as a correct response.

Originality/value

This work was inspired by methods of simulating the most common failures that occurs in amperometric gas sensors. For this purpose, simulations of the baseline shift and faults related to a power failure or a decrease in sensitivity were performed.