Anti-Corrosion Methods and Materials: Volume 47 Issue 3

Subjects:

Table of contents

A fuzzy approach to model RISK of MIC in a cathodically‐protected pipe

Reza Javaherdashti

Microbiologically‐influenced corrosion (MIC) is a type of corrosion in which, by its nature, many uncertainties exist. Using fuzzy logic, two models of MIC are modified to define…

357

Mechanism of corrosion inhibition by the 2‐chloroethyl phosphonic acid – Zn2+ system

S. Rajendra, B.V. Apparao, N. Palaniswamy

The synergistic effect of sodium salt of 2‐chloroethyl phosphonic acid (2‐Cl EPA) and Zn2+, in controlling corrosion of carbon steel in a neutral aqueous environment containing…

An examination of the cause of extensive corrosion of the shell of a 3CR12 conditioning tower in a cement plant

A. van Bennekom, J.H. Potgieter

The failure of a conditioning tower at a cement plant was investigated. It was found that the structure failed due to a combination of high temperature oxidation and sulphidation…

Anticorrosive performance of duplex systems on steel surfaces

N. Kouloumbi, G.M. Tsangaris, S. Mani, L. Givalos

Galvanized steel specimens were coated with four different organic systems, containing either special acrylic resins or epoxy resins with or without wash primer. The anticorrosive…

56
66
47
60
Cover of Anti-Corrosion Methods and Materials

ISSN:

0003-5599

Online date, start – end:

1954

Copyright Holder:

Emerald Publishing Limited

Open Access:

hybrid

Editor:

  • Professor Yu Yan